Click here to view .pdf version of catalog section.
Catalog# |
|---|
C600-1959 |
Catalog# |
|---|
T600-0466 |
Catalog# |
|---|
C600-2271 |
Aluminum body, Smooth jaws, Eyescrew handle, 5/8"-11 thread
Catalog# |
|---|
C600-1754 |
Aluminum body, Serrated jaws, Eyescrew handle, 5/8"-11 thread
Catalog# |
|---|
T600-2708 |
Catalog# |
|---|
C600-1743 |
Catalog# |
|---|
01-M-036 |
Catalog# |
|---|
C600-2255 |
Catalog# |
|---|
C600-2256 |
Aluminum body, Smooth jaws, Eyescrew handle, Pressure Terminal
Catalog# |
|---|
C600-2281 |
Catalog# |
|---|
C600-2282 |
Catalog# |
|---|
G1810-2 |
Catalog# |
|---|
G3622-1 |
Catalog# |
|---|
C600-1734 |
Catalog# |
|---|
C600-0197 |
* = IEC rating is Phase-Phase on 900 MCM conductor, ASTM rating is Phase-Ground on 900 MCM conductor
Catalog# |
|---|
HCDB-117 |
Catalog# |
|---|
C600-1735 |
Catalog# |
|---|
T600-1798 |
Catalog# |
|---|
C600-2231 |
Catalog# |
|---|
C600-2232 |
Catalog# |
|---|
G3363-1 |
Aluminum body, Smooth jaws, Eyescrew handle, 5/8"-11 thread
Catalog# |
|---|
C600-1733 |
Catalog# |
|---|
G3369 |
Catalog# |
|---|
C600-1732 |
These support studs can be installed on any pressure type terminal Ground Clamp, in place of the restraining strap immediately below the pressure terminal. The stud serves as a mechanical parking stand for a second clamp, preventing the clamp from making contact with the conductor or ground. This feature is particularly beneficial in three-phase grounding application.
Catalog# |
||
|---|---|---|
G3626 |
Compact 5" aluminum-alloy bar (5/8" diameter) accepts C type or duckbill clamps for phase-to-phase grounding technique. Hook style for attachment to tower angles.
Catalog# |
|---|
T600-1737 |
Bronze clamp is used to ground the bottom hinge contact on cutouts used on distribution riser poles or where grounding is required. It fits these cutouts: Chance F2, F3, and C Cutouts; Westinghouse LDX, Southern States B-80; Series 63; Joslyn; S&C Type SX; McGraw-Edison LMO, and GE Durabute. Clamp can be installed with or without grounding cable to aid as a warning and possibly avoid accidental closing of cutout. Clamp's drilled terminal accepts threaded-stud cable ferrules. It also accepts threaded L-Stud and T-Stud Terminals (3/4" diameter bronze) for use with conventional ground-clamp cable sets.
Catalog# |
|---|
C600-0785 |
Complies with OSHA 1910.269 for equipotential requirements near vehicles, underground gear, overhead switches and in substations.
Portable, Lightweight, High Performance
The EQUI-MAT™ Personal Protective Ground Grid provides an easy way to help establish an equipotential zone for a lineworker to stand on during various energized and deenergized work pratices. Properly applied, it accomplishes compliance with Occupational Safety and Health Administration (OSHA) 1910.269.
The EQUI-MAT™ Personal Protective Ground Grid easily can be taken anywhere needed, is simple to use, maintain and store. It consists of a high-ampacity tinned-copper-braid cable sewn in a grid pattern onto a vinyl/polyester fabric. Cable terminals permit connecting the mat's grid in series with an electrical ground and the subject system component or vehicle. Simply rinsing with water comprises all the care the mat requires. The mat may be folded and stored in a tool bag to help keep it clean and protected. Complete instructions are included with each unit.
Easy to use, versatile to many applications
Padmounted Transformers and Switches
Complies with OSHA 1910.269 for protecting workers operating and maintaining padmounted transformers and switchgear. The proper use of EQUI-MAT™ Personal Protective Ground Grid in these applications creates an equipotential zone just as a cluster bar (chain binder) does in overhead grounding pratices.
Mechanical Equipment (Vehicles, etc.) Grounding
It also helps provide compliance with OSHA 1910.269 for protecting workers around mechanical equipment which could become energized, such as utility vehicles and portable generators. For proper application, EQUI-MAT™ Personal Protective Ground Grids are attached to the vehicle (for example) at locations where workers could contact the vehicle.
Overhead Distribution and Transmission Switches
EQUI-MAT™ Personal Protective Ground Grid can help eliminate step and touch potential. Connect it to the handle of an overhead switch and stand on it when opening or closing the switch.
Similar uses for installing, maintaining or operating regulators, reclosures, capacitor banks.
If station ground mat integrity is questionable, apply the EQUI-MAT™ Personal Protective Ground Grid.
Simple to Join Multiples for Larger Areas
Cascading (or joining together) two or more mats is easy with the connecting tab and hardware furnished with each mat. So connected in series, the conductive grids become one. Whenever a larger area is needed, simply place lug connector tabs of two adjacent mats on the supplied bolt or threaded shank of a ball stud and secure with supplied washer and nut.
Each Basic Unit includes a Long Ball Stud and illustrated instructions.
Catalog# |
|
|---|---|
C600-2850 |
|
C600-2851 |
|
C600-2852 |
|
Portable reel quickly pays-out/takes-up, helps keep ground sets clean and neat, ready for use. Handles are comfortable, turned aluminum. Lightweight unit can be carried to remote sites or tubular-steel frame can be U-bolted to deck or truck. Galvanized drum has ribbed flanges to resist flexing and beaded rims to eliminate sharp edges. Reel is for storage only. Cable and clamps should be removed completely from reel before use. Failure to do so could result in a dangerous voltage drop and violent mechanical reactions. A label on the unit gives this warning.
Catalog# |
|---|
C417-6086 |
The Chance Screw Ground Rod provides a temporary ground where a system ground is not available. When installed, the 6' spiraled ground rod develops less resistance than straight ground rods. However, actual effectiveness depends upon soil properties. The reusable Ground rod is copper clad. The helix (spiral), handle and wing nut are bronze.
Catalog# |
|
|---|---|
G3370 |
This tool can be used to pickup loads and carry 250 Amps at 15KV. Rubber gloves should be worn while installing. The head has a floating washer to minimize conductor damage as the jaws are installed. The contacts are spring loaded and can be closed by pulling an insulated lanyard, putting the operator away from the tool during pickup operations. The contacts cannot be teased closed. The tool cannot be used as a load break tool as the operator cannot open the contacts while the tool is on the conductor. A fiberglass rod, attached to the end of the lanyard, is used to recock the contacts, but because it must be inserted through the head of the tool, the lineman must remove the tool from the conductor before recocking. An orange-tinted clear Lexan® housing permits easy visual inspection. A nylon handguard is used to keep the lineman's hand away from the energized area. By simply removing the two screws in the handguard, the tool can be disassembled for inspection and maintenance. All current carrying parts are copper or copper alloy and contacts are silver plated. The recommended 15KV jumper cables for this tool are #2 and 1/0. It is recommended that the Load Pick-Up Tool be inspected and cleaned after 25 operations or after 90 days. Clean all plastic parts with soft cloth, damp with ethyl alcohol only.
Catalog# |
|---|
C403-1631 |
The HASTINGS Load Pick-Up Tool can be installed with a shotgun stick or with rubber gloves. (In accordance with your company's safe work pratices.)
Both tools come completely self contained with cocking tool, firing lanyard, and safety latch. (Optional carrying case available.)
The Head Casting is an aluminum alloy and also serves as a storage port for the cocking tool.
Clear plastic housing below the head casting allows for quick, easy, and visual inspection.
Each tool comes complete with an Operating and Mainenance Manual.
Warning: These Load Pick-Up tools are NOT LOAD BREAK devices!
Catalog# |
|
|---|---|
6600 |
|
6605 |
|
01-089 |
Copper Grounding Cable is available in yellow and clear, is extra flexible for handling ease yet strong and tough for long wear. Jacketing is smooth, abrasion, weather and oil resistant in accordance with applicable ASTM Specifications, marked with AWG size approximately every 4 feet.
Yellow jackets are T-prene rubber compound with -20°F recommended low temperature. Clear jackets (which allow visual inspection of strand conditions) are ultraviolet-inhibited Poly Vinyl Chloride (PVC). Recommended low temperature for PVC-jacketed cable is 0°F.
Extra-flexible cables, because of their extra-fine strands, require termination ferrules when used with ground clamps.
Catalog# |
|||||
|---|---|---|---|---|---|
S6116 |
|||||
S6117 |
|||||
S6118 |
|||||
S6119 |
|||||
S6449 |
|||||
S7568 |
|||||
S6450 |
|||||
S6451 |
|||||
Unshrouded ferrules are available either factory-installed in pairs on any cable length specified or as separate individual units, the ferrules install simply with a hydraulic crimping tool. Complete illustrated installation instructions come with the ferrules and include a table for the crimping die sizes to use.
Catalog# |
|||||
|---|---|---|---|---|---|
C600-2606 |
|||||
C600-2607 |
|||||
C600-2608 |
|||||
C600-2609 |
Unshrouded ferrules are available either factory-installed in pairs on any cable length specified or as separate individual units, the ferrules install simply with a hydraulic crimping tool. Complete illustrated installation instructions come with the ferrules and include a table for the crimping die sizes to use.
Catalog# |
|||||
|---|---|---|---|---|---|
C600-2602 |
|||||
C600-2603 |
|||||
C600-2604 |
|||||
C600-2605 |
Catalog# |
||||
|---|---|---|---|---|
01-M-038-35-2 |
||||
01-M-038-1/0 |
||||
01-M-038-2/0 |
||||
01-M-038-4/0 |
Extremely flexible even at low temperatures, this cable features an insulation/jacket combination resistant to abrasion, oil, heat, moisture and ozone. The natural orange color of this mold-cured ethylene-propylene-base coating imparts high visibility. For easy identification, AWG size and voltage rating are embossed at 4-foot intervals.
For extended service life, an extruded screen interfaces insulation and conductor. This strand screen improves voltage-stress control by adding dielectric strength and eliminating internal corona.
Insulation and conductor screen meet and exceed ICEA-NEMA standard S-68-516.
For easy handling in diverse conditions, conductors are extra flexible alloy-coated copper-stranded rope per ASTM B-189 or B-33.
Ampacity ratings are based on 90°C conductor temperature at 40°C ambient.
Catalog# |
|||||
|---|---|---|---|---|---|
S10043 |
|||||
S10044 |
|||||
S10045 |
|||||
S10046 |
|||||
S11272 |
|||||
S11273 |
|||||
S11274 |
|||||
The T601-0040 Jumper Clamp has a larger contact opening for use on larger conductor distribution lines. The handle length below the handguard is 8-3/8". Easy to assemble, the connector assemblies are interchangeable between the 15 & 25 kV Jumper Clamps. The 400 amp continuous current rating is based on using 4/0 Jumper Cable on the tap side.
Catalog# |
|||||
|---|---|---|---|---|---|
T601-0040 |
The New Salisbury Sure-lok™ Jumper clamp is a revolutionary improvement over any other jumper clamp in the world. Featuring a ratchet type locking mechanism (patent pending), this is the only clamp available guaranteed not to loosen once installed on a line.
Loose Jumper clamps not only jeopardize your safety but can also cause fires and power outages. Even when torqued using wrenches or pliers, traditional clamps will eventually loosen from line vibrations and thermal cycling. This clamp tightens with a ratchet action using one hand, with no extra tools for a secure, positive connection. It can't come loose until you want it to. Pull and turn the locking knob and it loosens like any traditional clamp.
Catalog# |
|||||
|---|---|---|---|---|---|
1786 |
|||||
2116 |
SALCOR® Jumper Clamp not only provides a superior grip, but also resists ozone cutting and tracking. Being molded of rubber, these handles are inherently impact resistant and extremely durable. The body and jaw are made from a copper base alloy. The lower ring contact is made of self lubricating bronze. Assemble jumpers with insulated jumper cable and 5/8"-11 NC threaded ferrules.
Catalog# |
|||||
|---|---|---|---|---|---|
2260 |