3M 7642-S-2-2 Cold Shrink 2 Skirt Termination
Product image thumbnail 0
Product image thumbnail 1
$111.00/ea
Usually ships within 8 to 12 Days
EA
Adding...
Already a Customer? Log in to view your pricing
Manufacturer 3M
Mfg Catalog # 7642-S-2-2
Irby Part # 136020

Features

  • Provides a void-free seal to jacketed concentric neutral and concentric neutral power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions

Specifications

  • BIL: 110 kV
  • Breakout Boot: No
  • Cable Insulation Outside Diameter Range: 0.64-1.08 in
  • Cable Insulation Outside Diameter Range (Metric): 16.3-27.4 mm
  • Cable Shielding: Concentric Neutral (CN) - Jacketed Concentric Neutral (JCN)
  • Cable Type: Compact/Solid - Stranded
  • Conductor Size by Voltage: (5 kV) 8-4/0 AWG, (8 kV) 8-4/0 AWG, (15 kV) 8-4/0 AWG
  • Conductor Sizes: 2 AWG
  • Conductor Size Unit: AWG
  • Family: QT-III
  • Indoor/Outdoor: Outdoor
  • Insulation Level: 100% - 133%
  • Insulation Outer Diameter (Imperial): 0.87 in - 0.72 in - 0.66 in - 0.98 in - 0.96 in - 1.08 in - 1 in - 0.65 in - 0.74 in - 0.82 in - 1.06 in - 0.67 in - 0.69 in - 0.89 in - 0.95 in - 0.92 in - 0.83 in - 0.93 in - 0.68 in - 0.86 in - 0.77 in - 0.79 in - 0.94 in - 0.78 in - 1.03 in - 0.75 in - 1.01 in - 0.7 in - 0.88 in - 0.71 in - 1.07 in - 0.99 in - 0.85 in - 1.05 in - 0.76 in - 0.84 in - 0.97 in - 1.02 in - 0.8 in - 0.64 in - 1.04 in - 0.81 in - 0.91 in - 0.73 in - 0.9 in
  • Insulation Outer Diameter (Metric): 26.416 mm - 20.066 mm - 24.384 mm - 18.034 mm - 17.526 mm - 17.78 mm - 16.256 mm - 22.606 mm - 23.622 mm - 17.018 mm - 27.178 mm - 27.432 mm - 16.764 mm - 21.59 mm - 23.114 mm - 17.272 mm - 19.05 mm - 16.51 mm - 25.146 mm - 24.892 mm - 21.336 mm - 20.32 mm - 24.638 mm - 21.844 mm - 24.13 mm - 22.098 mm - 25.654 mm - 23.876 mm - 18.288 mm - 19.304 mm - 25.4 mm - 20.828 mm - 21.082 mm - 22.86 mm - 22.352 mm - 19.558 mm - 26.162 mm - 20.574 mm - 26.67 mm - 23.368 mm - 19.812 mm - 18.542 mm - 25.908 mm - 18.796 mm - 26.924 mm
  • Insulation Rejacketing: Yes
  • Maximum Installed Length: 9.80 in
  • Maximum Installed Length (Metric): 24.89 cm
  • Number of Conductors: 1
  • Number of Skirts: 2
  • RoHS EU Comments: Contact 3M for information
  • Termination Type: Single Termination
  • Voltage: 15 kV
  • Voltage Application: Medium Voltage

Overview

UPC 05400742013
Item Long Description 3M Cold Shrink QT III 7640 S, 7650 S & 7660 S Series Termination Kit includes a 1 piece, skirted termination. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 35kV.
GTiN 00054007420132
Type QT-III
Conductor Size 2 AWG
Applications Outdoor
Cable Type Concentric Neutral (CN); Jacketed Concentric Neutral (JCN)
Family Brand Name 3M
Voltage 15 kV
Number of Conductors 1

Your Product Lists

Log In or register for an account to gain access to the product groups feature!

You can create lists of products for regular needs, special projects, even use one as a wishlist.

Your Part Numbers

Log In or register for an account to assign your company part numbers to products!

No more memorizing or cross-referencing! Map your company's internal part numbers to items, then use your part numbers for searching and ordering.