3M 7693-T-150 Cold Shrink 3 Terms/Kit Non-Skirted Termination Kit
Product image thumbnail 0
Product image thumbnail 1
$675.00/ea
Usually ships within 8 to 12 Days
EA
Adding...
Already a Customer? Log in to view your pricing
Manufacturer 3M
Mfg Catalog # 7693-T-150
Irby Part # 136000

Features

  • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
  • 3M™ Cold Shrink QT-III Silicone Rubber Termination Kit 7620-T and 7690-T Series contains one-piece, non-skirted, silicone rubber terminations, meets IEEE Standard 48 Class 1 for indoor and weather-protected applications. The kits are designed for terminating solid dielectric shielded power cable rated 5–35 kV, with tape shield, wire shield and UniShield® constructions.
  • High dielectric-constant material regulates the distribution of electric field stress
  • Each kit contains sufficient quantities of material to make three single-phase terminations. The termination assemblies consist of a tubular insulator, high dielectric constant (Hi-K) stress control tube, conformable Hi-K stress controlling compound, and built-in environmental top seal. The insulator is made of a dark gray silicone rubber with advanced tracking resistant and hydrophobic properties. Note: Lugs need to be ordered separately. Exceptions: For T-150 Kits, 150 kV impulse level meets the impulse requirements for 35 kV class equipment where indoor terminations are used. 7620-T Kits are designed and assembled with stress controlling compound only.
  • Suitable for indoor applications
  • Non-tracking, molded, silicone rubber insulation offers durability
  • Includes 3 non-skirted, 1-piece, 3-phase, cold shrink terminations

Legal Disclaimer

  • The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.
  • Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.

Specifications

  • 3M ID: 80610834279
  • Agency Approvals: IEEE
  • Brand: 3M™
  • Breakout Boot: No
  • Cable Insulation Outside Diameter Range: 0.72-1.29 in
  • Cable Insulation Outside Diameter Range (Metric): 18.3-32.8 mm
  • Cable Shielding: Tape Shield || UniShield® || Wire Shield
  • Case Quantity: 1
  • Compatible Lug: QL2-A-2-250
  • Conductor Size by Voltage: (5 kV) 300-500 kcmil, (8 kV) 250-500 kcmil, (15 kV) 2/0 AWG-300 kcmil, (25/28 kV) 2-4/0 AWG, (35 kV) 2-2/0 AWG
  • Conductor Sizes: 1 AWG || 1/0 AWG || 2 AWG || 2/0 AWG || 250 kcmil || 3/0 AWG || 300 kcmil || 350 kcmil || 4/0 AWG || 400 kcmil || 500 kcmil
  • Family: QT-III
  • Indoor/Outdoor: Indoor Non-skirted
  • Insulation Level: 100% || 133%
  • Insulation Outer Diameter (Imperial): 0.72 in || 0.73 in || 0.74 in || 0.75 in || 0.76 in || 0.77 in || 0.78 in || 0.79 in || 0.8 in || 0.81 in || 0.82 in || 0.83 in || 0.84 in || 0.85 in || 0.86 in || 0.87 in || 0.88 in || 0.89 in || 0.9 in || 0.91 in || 0.92 in || 0.93 in || 0.94 in || 0.95 in || 0.96 in || 0.97 in || 0.98 in || 0.99 in || 1 in || 1.01 in || 1.02 in || 1.03 in || 1.04 in || 1.05 in || 1.06 in || 1.07 in || 1.08 in || 1.09 in || 1.1 in || 1.11 in || 1.12 in || 1.13 in || 1.14 in || 1.15 in || 1.16 in || 1.17 in || 1.18 in || 1.19 in || 1.2 in || 1.21 in || 1.22 in || 1.23 in || 1.24 in || 1.25 in || 1.26 in || 1.27 in || 1.28 in || 1.29 in
  • Insulation Outer Diameter (Metric): 18.288 mm || 18.542 mm || 18.796 mm || 19.05 mm || 19.304 mm || 19.558 mm || 19.812 mm || 20.066 mm || 20.32 mm || 20.574 mm || 20.828 mm || 21.082 mm || 21.336 mm || 21.59 mm || 21.844 mm || 22.098 mm || 22.352 mm || 22.606 mm || 22.86 mm || 23.114 mm || 23.368 mm || 23.622 mm || 23.876 mm || 24.13 mm || 24.384 mm || 24.638 mm || 24.892 mm || 25.146 mm || 25.4 mm || 25.654 mm || 25.908 mm || 26.162 mm || 26.416 mm || 26.67 mm || 26.924 mm || 27.178 mm || 27.432 mm || 27.686 mm || 27.94 mm || 28.194 mm || 28.448 mm || 28.702 mm || 28.956 mm || 29.21 mm || 29.464 mm || 29.718 mm || 29.972 mm || 30.226 mm || 30.48 mm || 30.734 mm || 30.988 mm || 31.242 mm || 31.496 mm || 31.75 mm || 32.004 mm || 32.258 mm || 32.512 mm || 32.766 mm
  • Insulation Rejacketing: No
  • Lug/Stem Connector Included in Kit: No
  • Manufacturing Origin: USA
  • Maximum Installed Length: 16.00 in
  • Number of Conductors: 1
  • Voltage: 15 kV || 25 kV || 35 kV || 5 kV || 8 kV
  • Voltage Application: Medium Voltage

Overview

UPC 05400741778
Item Long Description Quick installation with versatile one-piece designNo torches, heat or special tools requiredHi-K stress controlExcellent tracking resistanceIncludes everything required to make 3 terminations (except lugs)
GTiN 00054007417781
Voltage 35 kV
Type QT-III
Conductor Size 1 AWG; 1/0 AWG; 2 AWG; 2/0 AWG; 250 MCM; 3/0 AWG; 300 MCM; 350 MCM; 4/0 AWG; 400 MCM; 500 MCM
Applications Indoor
Cable Type Tape Shield; UniShield(R); Wire Shield
Family Brand Name 3M
Indoor Outdoor Indoor Non-skirted

Your Product Lists

Log In or register for an account to gain access to the product groups feature!

You can create lists of products for regular needs, special projects, even use one as a wishlist.

Your Part Numbers

Log In or register for an account to assign your company part numbers to products!

No more memorizing or cross-referencing! Map your company's internal part numbers to items, then use your part numbers for searching and ordering.